Hozelock Cyprio Bioforce Pressure Filters Replacement Parts

Write a Review

Starts at: $17.48

Brand: Hozelock Cyprio

SKU:Z12155

MPN: 5114

Parts for BioForce Pressure Filter Pre-2002 & Post-2002:

 

Part Description

BioForce 250 Part #

BioForce 500 Part #

BioForce 1000 Part #

BioForce 2000 (1314) Part #

2000 Gal Pond-1250 gph Max

Lid Clips/Clamps

Z12155

Z12155

Z12155

Z12365

Hose Tails

Z12225

Z12225

Z12225

Z12325

Foam - Traditional

1321 (Pre-2002)

 

1324 (Post-2002)

1321 (Pre-2002)  - 1 piece

 

1305 (Post-2002) - 7.5" diameter.  Includes 2 pads, one medium (Top) and one fine (Bottom). 7.25" Diameter x 3.625" High.

1322 (Pre-2002 DISCONTINUED]

(Two 1305's stacked can sub for one 1322)     

 

1306 (Post-2002- 3 Pieces

1323

Foam - Matala

Not Available (Pre-2002)

MM1324 (Post-2002)

Not Available (Pre-2002)

M1305 (Post-2002)

Not Available (Pre-2002)

M1306 (Post-2002)

M1323

Lid

Z12135(Pre-2002)

Discontinued

Z12136 (Post-2002)

Discontinued

Z12135(Pre-2002)

Discontinued

Z12136 (Post-2002)

Discontinued

Z12135(Pre-2002)

Discontinued

Z12136 (Post-2002)

Discontinued

Not Available

Body Chamber

Z12115 (Pre-2002)

Z12116 (Post-2002)

Z12115 (Pre-2002)

Z12116 (Post-2002)

Discontinued

Z12125 (Pre-2002)

Z12126 (Post-2002)

Not Available

Cleaning Indicator

Not Available

Z12216

Not Available

Z12216

Not Available

Z12217

Lid O-Ring

Not Available

Z12335

or

Z12076

Z12335

or

Z12076

Z12305

Outlet Head(Non-UV)

Z12176

Z12176

Z12176

Z12335 (DISCONTINUED )

Outlet Head(UV)

Z12145 (Pre-2002)

Z12146 (Post-2002)

Z12145 (Pre-2002)

Z12146 (Post-2002)

Z12145 (Pre-2002)

Z12146 (Post-2002)

DISCONTINUED (Pre-2002)

84230 (Post-2002)

UV Bulb

C101 9W (Pre-2002)

C100 5W(Post-2002)

C101 9W (Pre-2002)

C100 5W(Post-2002)

C101 (9W)

C101 9W (Pre-2002)

C103 13W(Post-2002)

Quartz Tube

1527 (Pre-2002)

1523 (Post-2002)

1527 (Pre-2002) (DISCONTINUED)

1523 (Post-2002)

1527 (Pre-2002) (DISCONTINUED)

1523 (Post-2002)

1528 (Pre-2002)

1524 (Post-2002)

Service Kit

UAQC01 (Pre-2002)

Discontinued

Not Available (Post-2002)

1317 (Pre-2002)

1337(Post-2002)

1318 (Pre-2002)

1338(Post-2002)

1319 (Pre-2002)Does NOT include UV Bulb

Not Available (Post-2002)

Both Discontinued

Service Kits Contents: complete set of seals, foam, and UV lamp (1319 Service Kit does NOT include a UV bulb)

Cyprio 500 Perforated Tube - 500perftube

Question: How do I know if my BioForce is Pre-2002 or Post-2002?

Answer:  The only Bio Force filters that it really makes a difference are 500 and 1000. If the filter media inside both units is one piece, it is pre 2002. If the filter pads are 2 pieces for the 500 and 3 pieces for 1000, then it is post 2002. The Bio Force 2000 has always had 3 pieces to complete it's filter pads. 

Question: I cannot remember the order of the filters for my BioForce 2000

AnswerCoarse on bottom, medium in middle and fine on top.


 Question:Will the 2000 Quartz Tube 1524 work with Pre2002 and Post 2002 BioForce 2000's?

Answer: The 1524 will work on both. If pre 2002, they simply take the back plastic piece off the end off the tube. If post 2002, the black plastic piece is used to attached the tube. So, the same quartz tube will work on both

Cyprio Hozelock Pond Filter Parts 

  • Hozelock Cyprio manufactures BioForce UVC Pond Filters designed to keep your pond fresh by treating the water with a foam-sleeve filter and an ultraviolet bulb. The unit comes in different sizes, ranging from 250- to 4,000-gallon capacities, to suit your needs. These filter parts are the same for all, but come in different sizes. Verify the size and model number of your filter when ordering parts.

Canister

  • The filter canister is the body of the unit and houses the filter sleeve with the lid on top.

UV Lamp

  • The lamp goes on the top of the unit and treats the water with ultraviolet rays. This treatment improves the clarity of the water by killing algae growth and harmful bacteria.

O-Ring Seals

  • These washer rings form a watertight seal wherever anything is attached to the filter canister, such as lids and plumbing lines. Install them as you assemble the unit.

Cleaning Indicator

  • The red button on top of the unit is a cleaning indicator that pops up when the filter needs cleaning.

Inlet and Outlet Connections

  • These connections are transitional in that the tapered head allows them to connect more easily to varying sizes of hoses. They are located on top of the unit.

Lid and Clips

  • The lid is the removable top that caps the canister. This lid is attached by seven clips to clamp it to the canister, holding it in place.

Foam Filters

  • BioForce filters are foam sleeves. These sleeves filter the water with beneficial bacteria that accumulates on the bottom third of the filter sleeve and through the foam itself. The foam filter fits inside the canister when the lid is removed.

 

Bioforce 250 - Pre 2002 

 

Bioforce 250/500 - Post 2002 

 

Bioforce 500/1000 - Pre 2002 

 

Bioforce 1000 - Post 2002 

 

Bioforce 2000 - Pre & Post 2002

 

Bioforce 250/500/1000 UVC - Pre 2002

 

Bioforce 250/500/1000 UVC - Post 2002

 

 BIOFORCE FILTERS - All Models Discontinued

PRODUCT # MODEL DESCRIPTION MAX POND SIZE MAX FLOW RATE FILTER HEIGHT FITTING RANGE
CYP 1301 250 BIOFORCE 250 FILTER 250 GAL. 125 GPH 11" 3/4" - 1"
CYP 1302 500 BIOFORCE 500 FILTER 500 GAL. 250 GPH 11" 3/4" - 1"
CYP 1303 1000 BIOFORCE 1000 FILTER 1000 GAL. 500 GPH 17" 3/4" - 1"
CYP 1304 2000 BIOFORCE 2000 FILTER 2000 GAL. 1000 GPH 20" 3/4", 1", 1 1/4" or 1 1/2"

Cyprio BioForce™

Finally, an easy to use versatile filter. This pressurized filter can be used above ground or buried up to its lid. A unique feature on this unit is the red button on the lid that pops up when the filter needs cleaning. These filters are available with or without UVC lights. All units can be converted in the field to a UVC unit by removing the center chamber and adding a UVC Kit. The inlet and outlet are transitional style fittings that allow the filter to connect to several different sizes of hose or tubing. For specific sizes, please see chart below. The Cyprio 2000 has three densities of foam media that trap debris while promoting colonization of beneficial bacteria. The bottom chamber of bio-spheres also enhances the growth of beneficial bacteria. The BioForce filter is easy to install, easy to clean, and easy to use!

Question:

My old BioForce 1000 had a DeSludge tube which is now missing. What does it do?

Answer:

I only remember it on the early models. These units did not have the cleaning indicator. The spot where these indicators are on the lid, there was a screw off cap. When you wanted to back flush, you took the cap off and turned on your pump. The tube that the lady is missing was mounted under this hole in the lid. It would allow dirty water from the bottom of the tank to flow up pipe and out the top of the lid. Usually a hose was screwed on to this opening and dirty water could be pumped away from pond. This pipe is not needed for regular use of filter,  only when back flushing.

Reviews


Get updates about specials, announcements, and seasonal sales